Page 393 - Keubler Motion Sensors
P. 393

Linear measuring technology




             Incremental magnetic measurement system
             sensor head, magnetic band                  Limes LI50 / B2             Resolution min. 5 µm
        www.HydroSanatSharif.com
            Terminal assignment

              Output circuit   Type of connection   Cable
                                  Signal:       0 V   +V    A          B           0           )
                1, 2       1
                                  Cable colour:    WH    BN    GN    YE    GY    PK    BU    RD    shield  1)


            Dimensions
            Dimensions in mm [inch]
            Sensor head Limes LI50                             Magnetic band Limes B2        10
                                     3.5 [0.14]
                             40  [1.57]   ]  8
                                          2
                     4 [0.16]  17  [0.67]  .  0  10,2 [0.4]
                                          7 [
                      ]
                      8  ]  6
                      9
                      .  1
                      0  .
                      [  0
                         [
                      5     4
                      2
                                                                2   Length L, max. 50 m                 3
                                 1                                                     2
                                                                3     Masking tape                      4
                                                                                                        5
                                                                4     Magnetic band
                                                                                                  1.56
             1     Active measuring area                        5     Carrier band                1.97
                                                                                                                    Linear measuring   technology


            Permissible mounting tolerances

            Tilting                          3°              Torsion
                                                                         3°

                    8,5 [0.33]
                                                             Offset      1
                     6



             6     Distance sensor head / magnetic band:
               0.1 ... 2.0 mm (recommended 1 mm)























            1)  PH = Shield is attached to connector housing.
            © Fritz Kübler GmbH, subject to errors and changes. 02/2015                        www.kuebler.com  391